Phy alarm generation, Mac error injection – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 411

background image

Ethernet Tabs

SONET/SDH Application

397

Error/Alarm TX

PHY Alarm Generation

³

Type: The following alarms are available:

³

On/Off button: The On/Off button is used to activate/deactivate the
selected alarm. This setting is disabled (Off) by default.

MAC Error Injection

³

Type: The following error is available with both manual and automated
injection modes: FCS.

³

Amount: Allows the selection of the amount of manual error to be
generated. Choices are 1 through 50. The default setting is 1.

³

Send button: Press Send to manually generate error(s) according to
the error type and the amount of selected error.

³

Rate: Press the Rate field to select the rate for the automated error.
Choices are: 1.0E-02, 1.0E-03, 1.0E-04, 1.0E-05, 1.0E-06, 1.0E-07,
1.0E-08, 1.0E-09 or user definable from 1.0E-09 to 1.0E-02. The default
setting is 1.0E-04.

Type

Avaialble with

Ethernet Gb Ethernet 10G Ethernet

Local Fault Generates a local

fault sequence.

X

X

Remote Fault: Generates a

remote fault sequence.

X

X

X

Link Down: Generates a

continuous PCS error (block

error). Not available with 10G

Ethernet mapped in GFP.

X