Alarm analysis, Frequency analysis – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 530

background image

Common Tabs

516

IQS-8100 Series Transport Blazer

Client Offset RX

Alarm Analysis

Frequency alarm indicates that the received client signal rate meets the
standard rate specifications (green) or not (red). Not available with
ODUflex CBR when Frequency Offset Analysis is disabled.

Frequency Analysis

The IQS-8100 Series allows the following frequency monitoring range.

Frequency (bps) indicates the frequency of the input signal in bps.

Client

Standard Rate Specification

Gb Ethernet

1250000000 ± 131875 bps (±105.5 ppm)

ODUflex CBR

Expected RX rate ±105.5 ppm

(See Expected Frequency (bps) on page 515)

Client

Measurement range

Gb Ethernet

1250000000 ± 150000 bps (±120 ppm)

ODUflex CBR

Expected RX rate ±120 ppm

(See Expected Frequency (bps) on page 515)