OTN Tabs

SONET/SDH Application

187

ODU TTI/FTFL TX

FTFL TX

Allows the configuration of the Forward and Backward ODU Fault Type
Fault Location (FTFL) to be generated.

³

Fault Indication and Fault Indication Code allows the selection of the
FTFL fault indicator message/code (byte 0 for forward, byte 128 for
backward) to be generated. The default setting is No fault (00).
Choices are:

Note: The Fault Indication Code field is automatically updated when the Fault

Indication is changed and vice versa.

Binary allows either displaying the Fault Indication Code in binary
(when enabled) or hexadecimal (when disabled). This setting is
disabled by default.

Fault Indication

Fault Indication Code

No fault

00

Signal fail

01

Signal Degrade

02

Reserved

03

a

a.

Selecting Reserved will use the hexadecimal code 03 but, all codes from 03 to FF

are reserved for future international standardization.