Alarm analysis – EXFO IQS-8100 Series Transport Blazer for IQS-600 User Manual

Page 247

background image

SONET Tabs

SONET/SDH Application

233

Line RX (SONET)

For OC-768: The REI-L error is declared when the combination of the
M0 and M1 bytes indicates that one or more BIP violations have been
detected.

Alarm Analysis

³

AIS-L (Alarm Indication Signal - Line): The AIS-L alarm is declared
when bits 6, 7 and 8 of the K2 byte contain the “111” pattern in five
consecutive frames.

³

RDI-L (Remote Defect Indication - Line): The RDI-L alarm is declared
when bits 6, 7, and 8 of the K2 byte contain the “110” pattern in five
consecutive frames.

M0

Located in STS-1 #4

M1

Located in STS-1 #7

Indicates

0000 0000

0000 0000

0 BIP violation

0000 0000

0000 0001

1 BIP violation

0000 0000

0000 0010

2 BIP violations

:

:

0001 1000

0000 0000

6144 BIP violations

0001 1000

0000 0001

0 BIP violation

:

:

1111 1111

1111 1111

0 BIP violation