Common Tabs

SONET/SDH Application

493

HOP/LOP Pointer Adjust TX (SONET/SDH)

Pointer Steps

³

Increment

For HOP: Select the number of positive pointer adjustment to include
into the STS-n (SONET) or AU-n (SDH). For multiple pointer
adjustments, the pointer adjustment rate is 1 adjustment at every 4
frames. Choices are 1 to 1000. The default setting is 1.

For LOP: Select the number of positive pointer adjustment to include
into the VTn (SONET) or TU-n (SDH). For multiple pointer adjustments,
the pointer adjustment rate is 1 adjustment at every 4 multiframes.
Choices are 1 to 1000. The default setting is 1.

³

Decrement

For HOP: Select the number of negative pointer adjustments to include
into the STS-n (SONET) or AU-n (SDH). For multiple pointer
adjustments, the pointer adjustment rate is 1 adjustment at every 4
frames. Choices are 1 to 1000. The default setting is 1.

For LOP: Select the number of negative pointer adjustments to include
into the VTn (SONET) or TU-n (SDH). For multiple pointer adjustments,
the pointer adjustment rate is 1 adjustment at every 4 multiframes.
Choices are 1 to 1000. The default setting is 1.

³

Send buttons: Press the corresponding Send button to send positive or
negative pointer adjustments.