Page 539

background image

System Tab

SONET/SDH Application

525

Clock Synchronization

³

Frequency: The Frequency alarm indicates if the received signal rate
meets (green) or not (red) the following rate specifications.

Frequency Analysis

³

Frequency (bps) displays the received signal rate in bps for DS1 and
E1 interfaces and in Hz for 2 MHz interface.

³

Frequency Offset displays the positive or negative frequency offset
between the standard rate specification and the rate from the received
signal. Frequency unit can be set to bps, or ppm for DS1/E1 and is set
to Hz for 2 MHz. The default setting is bps for DS1/E1 and Hz for 2 MHz.

Signal

Rate specification

DS1

1544000 ±15 bps (±9.2 ppm)

E1

2048000 ±19 bps (±9.2 ppm)

2MHz

2048000 ±19 Hz (±9.2 ppm)