Deleting a processor file from the workspace, 5œ13, Offline config – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual
Page 80

Creating and Configuring Processor Files
5–13
Deleting a Processor File from the Workspace
Deleting a file from the workspace physically removes it from the memory of the
terminal, but the file resides in the processor’s memory and on the terminal hard
disk.
1.
At the main menu press
CONFIG
OFFLINE
CONFIG
OFFLINE
PRG/DOC
F3
, then
CONFIG
OFFLINE
CONFIG
PROCSSR
FUNCTNS
F1
. The following menu
appears:
F1
F2
F6
F7
F3
F4
F8
CHANGE
PROCSSR
CHANGE
PASSWRD
CREATE
FILE
DELETE
FILE
CHANGE
PR. NAME
CHANGE
FL. NAME
MONITOR
FILE
Press a key, enter file number or file name
offline
SLC 5/03
File EXAMPLE
PROGRAM DIRECTORY FOR PROCESSOR: EXAMPLE
F5
CLEAR
MEMORY
F9
F10
DATA
MONITOR
FILE
PROTECT
FILE
PROTECTED
NAME
TYPE
SIZE (words)
0
system
*
1
reserved
*
2
No
ladder
*
2.
Press
CONFIG
OFFLINE
CONFIG
CLEAR
MEMORY
F5
, then
CONFIG
OFFLINE
CONFIG
YES
F8
to clear the file in the workspace, or
CONFIG
OFFLINE
CONFIG
NO
F10
to abort the operation.
3.
Press either
CONFIG
OFFLINE
CONFIG
RETURN
TO MENU
F3
or
CONFIG
OFFLINE
CONFIG
CHANGE
FILE
F4
.
- 20P PowerFlex DC Drive - Frame D Bimetal Thermostat (10 pages)
- 1336S_F_T_E_R F Frame Snubber Resistor Repl. (6 pages)
- 22-COMM PowerFlex 4-Class DSI (Drive Serial Interface) Network Communication Adapter (4 pages)
- 8-545 Plug In Solid State Relay (2 pages)
- 20-HIM-B1 PowerFlex 7-Class HIM Bezel (DPI) (4 pages)
- 100 Contactors with DC Coil (1 page)
- 100 Contactors with DC Coil (2 pages)
- 20P PowerFlex DC Drive - Frame D Switching Power Supply Circuit Board (6 pages)
- 140G-MTFx_MTHx_MTIx_MTKx Trip Unit Installation-140G-M (6 pages)
- 45BRD Analog Laser Sensor (4 pages)
- 20D Multi-Device Interface Option Board for PowerFlex 700S Drives (20 pages)
- 56RF RFID 18 mm Cylindrical Transceiver (2 pages)
- 42KC Miniature Rectangular: 5V DC Version (2 pages)
- 20P PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board (16 pages)
- 21P-MISC-A-TP-2 Transition Tube Kit #C19-6/7 For PowerFlex 755 w/OEM Liquid Cooling Fr 6/7 Drive (2 pages)
- 42BT Background Suppression Sensor (3 pages)
- 42CB High Speed 18mm Cylindrical (4 pages)
- 140EX-JE2_JE3 Molded Case Circuit Breaker (4 pages)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (1 page)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (3 pages)
- 20-HIM-A6 PowerFlex (Human Interface Module) (74 pages)
- 42CF General Purpose 12mm Cylindrical (4 pages)
- 20D PowerFlex 700S Phase II Drive Frames 1...6 (80 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (6 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (4 pages)
- 20B PowerFlex 700 Custom Firmware - Pump Off (12 pages)
- 20-WIM-N4S DPI Wireless Interface Module (92 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (7 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (2 pages)
- 60-2619, 42JS Swivel/Tilt Mounting Bracket (1 page)
- 22A PowerFlex 4/40/400 Flange Mount (4 pages)
- 45MLA Controller Installation Instructions (16 pages)
- 20P PowerFlex DC Drive - Cooling Fan for Frame A Drives Above 73A at 230V 460V AC (6 pages)
- 42JS Series 7000 to 42JS VisiSight Replacement Kit (2 pages)
- 22A PowerFlex 4-Class HIM Bezel (DSI) (4 pages)
- 42CS Stainless Steel Photoelectric Sensors (4 pages)
- 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger (40 pages)
- 20P PowerFlex DC Drive - Frame B SCR Modules (20 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (161 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (22 pages)
- 22F PowerFlex 4M Input RFI Filters (2 pages)
- 45LFM Capacitive Label Sensor (4 pages)
- 140G-Rx Installation Instruction-140G-R (2 pages)
- 140G-Rx Installation Instruction-140G-R (29 pages)
- 22C PowerFlex 400 AC Drive Quick Start - FRN 1-4.xx (28 pages)