APS Error Messages
A–9
Display Message
Recommended Action
Description
FATAL DISK ERROR
A failure occurred while trying to load the
data base from disk or trying to save the
data base to disk.
1) Retry the function, 2) restart APS from
the DOS command prompt; then 3)
verify your disk validity by running
CHKDSK." Contact your RSI
representative if the above actions do
not help.
FATAL ERROR - RUNG BRANCH
CONTAINS MORE THAN 75 LEVELS
During create reports a rung was
detected having more than 75 levels on
a branch.
Change the rung to have no more than
75 levels. Retry the function.
FATAL ERROR CLOSING FILE
An unknown error occurred when APS
tried to read from a file.
Either 1) retry the function; 2) restart the
software; 3) reboot the PC; or 4) run
CHKDSK" from the DOS command
prompt.
FATAL ERROR INITIALIZING
DOCUMENTATION FILES
An error occurred during an initialization
of the current data base after you
requested to rename the current file.
1) Retry the function, 2) restart APS from
the DOS command prompt; then 3)
verify your disk validity by running
CHKDSK." Contact your RSI
representative if the above actions do
not help.
FATAL ERROR OPENING FILE
An unknown error occurred when APS
tried to read from a file.
Either 1) retry the function; 2) restart the
software; 3) reboot the PC; or 4) run
CHKDSK" from the DOS command
prompt.
FATAL ERROR READING FROM FILE
An unknown error occurred when APS
tried to read from a file.
Either 1) retry the function; 2) restart the
software; 3) reboot the PC; or 4) run
CHKDSK" from the DOS command
prompt.
FATAL ERROR SAVING
DOCUMENTATION FILES
An error occurred during a save of the
current data base after you requested to
rename the current file.
1) Retry the function, 2) restart APS from
the DOS command prompt; then 3)
verify your disk validity by running
CHKDSK." Contact your RSI
representative if the above actions do
not help.
FATAL ERROR WRITING TO FILE
An unknown error occurred when APS
tried to write to a file.
Either 1) retry the function; 2) restart the
software; 3) reboot the PC; or 4) run
CHKDSK" from the DOS command
prompt.
FATAL INTERNAL ERROR
Either 1) APS was not able to allocate
memory from DOS while you were
reviewing/editing comments or symbols;
or 2) APS was initializing and could not
allocate DOS memory for internal data
storage.
Verify your disk validity by running
CHKDSK" from the DOS command
prompt. We recommend 525K bytes
available for APS 3.01, 550K bytes
available for APS 4.0, 250K bytes
available for APS 5.0, and 300K bytes
available for APS 6.0.