The multi-point list menu, 18œ3, Offline config – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual
Page 348: The following screen appears

The Multi-Point Function
18–3
The Multi-Point List Menu
You can access the multi-point list when online or offline from the monitor file
display by pressing
CONFIG
OFFLINE
CONFIG
MULTI
F4
POINT
. The following screen appears:
F10
Press a function key
REM PROG
no forces
EDITS: NONE
PROC Addr 1
EXIT
F3
TOGGLE
STATE
F5
F6
VIEW
OFFLINE
COPY TO
OFFLINE
F1
EDIT
FIELDS
F2
DISPLAY
SYMBOLS
F7
FORCE
ESC exits
MULTIPOINT
POINT ADDRESS
STATE
DESCRIPTION
0
I:2.0/15
1
Gate OPEN
1
N7:0/12
0
P/N is even
2P
O:3.0/0
1
Motor STARTED
3P
I:1.0/3
1
LS1 Actuated
4
B3/3
0
target file=15
5P
B3/4
1
barcode data OK
6
O:3.0/2
1
Diverter RIGHT
7
I:2.0/0
0
8
I:2.0/1
1
Overtravel RIGHT
9
I:2.0/2
0
10P
I:2.0/3
1
Overtravel DOWN
11
B3/10
0
Machine Idle
12
B3/11
0
Normal Storage
13
O:3.0/12
0
Laser OFF
Point: The number of the entry in the multi-point list. If the entry is protected
(read-only), the letter P appears to the right of the entry number. See page 18–4 for
more information on protection.
Address: Displays the address within the data table that is being monitored.
State: Shows the current state of the monitored bit (i.e., 0, 1, 0FON, 1FON, 0FOF,
1FOF, FON, FOF).
Description: Displays a description of up to 16 characters. Separate descriptions
can be entered for the ON and OFF states. The SLC 5/03 and SLC 5/04 processors
store these descriptions in the controller’s memory.