Display Message
Recommended Action
Description
ILLEGAL SYMBOL
During configuration of report options for
the cross reference report an illegal
starting or ending symbol was entered.
Enter a valid symbol and retry the
function.
IMMEDIATE FLOATING POINT IS NOT
SUPPORTED BY THIS PROCESSOR
A preĆSLC 5/03 Series B processor is
configured.
Either change the processor to an SLC
5/03 Series B or SLC 5/04 processor, or
change the ladder program to not
include floating point values.
IMMEDIATE FLOATING POINT VALUE
IS NOT ALLOWED
The instruction parameter does not
support floating point values.
Either change the processor to an SLC
5/03 Series C or SLC 5/04 processor, or
select a different instruction.
INCOMPATIBLE DEVICE
The version of the software is unable to
communicate with the requested device.
Contact your RSI representative.
INCORRECT BOARD ADDRESS OR
IRQ - DRIVER HAS SET CORRECT
VALUES
(This message only appears when one
1784ĆKT2 interface module is installed.)
When configuring the 1784ĆKT2
communication interface module, an
incorrect board address or IRQ was
entered.
No action required. The 1784ĆKT2
interface module sets the correct board
address or IRQ value.
INCORRECT COMMUNICATION
BOARD IRQ CONFIGURATION
The IRQ address for a 1784ĆKT2,
1784ĆKL, or 1784ĆKT interface module
was entered incorrectly in the online
configuration. This message also
appears when more than one 1784ĆKT2
interface modules are installed.
Verify the correct IRQ address on the
interface module and change the
parameter in the online configuration set
up. Retry the function.
INCORRECT COMMUNICATION
BOARD ADDRESS CONFIGURATION
The board address for a 1784ĆKL or
1784ĆKT interface module was entered
incorrectly in the online configuration.
This message also appears when more
than one 1784ĆKT2 interface module is
installed.
Verify the correct board address on the
interface module and change the
parameter in the online configuration set
up. Retry the function.
INPUT INVALID, PLEASE REENTER
Incorrect syntax entered.
Retry the function.
INPUT MIN. MUST BE LESS THAN
INPUT MAX.
An attempt was made to enter a Scale
with Parameters instruction having an
input minimum constant operand greater
than the input maximum constant
operand.
Either make the input maximum value
greater than the input minimum value, or
change one of the operands to a
nonĆconstant value.
INPUT, OUTPUT, AND STATUS FILES
CANNOT BE CONSTANT PROTECTED
An attempt to constant protect these
types of files was made.
Apply only static protection to these
types of files.
INSTRUCTION HAS NO OPERANDS
`Modify symbol' was selected, but the
instruction does not have any operands.
Informational message. No action
necessary.
INSTRUCTION HAS NO OPERANDS
TO RELATE TO SYMBOL
The instruction has operands, but none
of the operands support a symbol name.
ReĆenter the user instruction address.