beautypg.com

Preface, Interchange dh-485 – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual

Page 226

background image

Preface

Advanced Programming Software User Manual

11–32

Interchange DH-485

The Interchange DH-485 option is available when using any of the SLC 500
processors with a 1747-PIC Interface Converter, the 1784-KTX interface card, or
with the 1784-PCMK card and a 1784-PCM4 cable.

Note

You must edit the initialization file (cfg_kt.ini) found in the INTERCHANGE
directory in order to use the Interchange DH-485 option. To do this, use the
INTERCHANGE Device Configuration utility that was loaded during the APS
installation procedure. Refer to chapter 1 in this manual for configuration
information.

If the the INTERCHANGE driver is not loaded or the INTERCHANGE port selected
is not configured for use, all entries in the online configuration screen will display
asterisks (*), except SLC node addresses and the current INTERCHANGE port.

For cabling information, see the SLC 500 Modular Hardware Style Installation and
Operation Manual
, Publication 1747-6.2.

Comm. Port

COM1

Current Device

DH-485

Baud Rate

57600

Terminal Address

0

F5

PROC Address

1

MAX Node Address

31

F8

Curr. Interchange Port

1

F9

Save to File

F9

Press a function key

SAVE TO

FILE

ESC exits/Alt-U aborts changes

ONLINE CONFIGURATION

F8

NEXT

PORT

F5

PROC

ADDRESS

F2

SELECT

DEVICE

Function Key

Description

[F2] Select Device

Toggles between the selected device driver and the device

driver selection menu.

[F5] Processor Address

Allows you to select a processor address as a node number.

Valid range is 0–77 octal. The default is 1.

[F8] Next Port

Allows you to select the port number where the interface card

is installed. Valid range is 1–8. The default is 1.

[F9] Save to File

Saves the selected parameters to a user file.