Depending on the form of protection, one of the following prompts is displayed:
•
Enter list of files to apply static protection
•
Enter list of files to apply constant protection
•
Enter list of files to remove static and/or
constant protection
If you attempt to change the protection of an already protected file, APS detects
this request. In this example, R6:10 is already statically protected. The
following display appears if protection is detected:
FILE
TYPE
LAST ADDRESS
ELEMENTS WORDS
FILE PROTECTION
0
O output
O:2
1
1
1
I input
I:3
2
2
STATIC MEM-MOD
2
S status
S:82
83
83
STATIC MEM-MOD
3
B binary or bit
B3/15
1
1
MEM-MOD
4
T timer
T4:10
11
33
5
C counter
C5:10
11
33
CONSTANT
6
R control
R6:10
11
33
STATIC
7
N integer
N7:255
256
256
8
F floating
F8:0
1
2
PROCESSOR MEMORY LAYOUT
391 data words of memory used in 9 data table files
266 instruction words of memory used in 3 program files
3732 instruction words of unused memory available
File(s) already STATIC Protected. DO you wish to alter protection?
offline
SLC 5/03
File EXAMPLE
DATA TABLE MAP
File 8 only applies to SLC
5/03 OS301, OS302 and
SLC 5/04 OS400, OS401
processors.
F10
NO
F8
YES
The above prompts only appear if you attempt to change the form of protection
for one or more data table files. If you press
CONFIG
OFFLINE
CONFIG
YES
F8
, all of the files in the
list will have their protection changed. If you press
CONFIG
OFFLINE
CONFIG
NO
F10
, the entire
request is cancelled and protection is not changed.
If the file is Constant protected and you want to change it to Static protection,
the prompt:
File(s) already CONSTANT protected. Do you
wish to alter protection?
is displayed.