To configure the 1770-KF3 or 1747-KE, begin by pressing
CONFIG
OFFLINE
CONFIG
DEVICE
CONFIG
F7
. The
Device/Modem/Full-Duplex configuration menu appears.
F9
Press a function key
SAVE
TO FILE
F1
Baud Rate (PC to KF3/KE)
1200
F2
Parity
NONE
F3
Error Check
CRC
F4
Use Modem (Flow Control)
YES
F5
Dial Phone Number
YES
F6
Modem Init String
AT L1 &M &C1 &D2 &S1 &W DT
F7
Phone Number
F8
Auto Disconnect
0 (minutes)
F9
Save to File
F10
Full Duplex Configuration
F1
BAUD
RATE
F2
PARITY
F4
USE
MODEM
ESC exits/Alt-U aborts changes
KF3/KE/Modem/Full Duplex Configuration
F7
PHONE
NUMBER
F3
ERROR
CHECK
F10
FULL
DUPLEX
F5
DIAL
PHONE #
F6
MODEM
INIT
F8
AUTO
DISCNCT
Function Key
Description
[F1] Baud Rate (PC to KF3/KE)
Toggles between 300, 1200, 2400, 4800, 9600, and 19200.
The default is 1200. This selection is only for communication
between your personal computer and the 1770ĆKF3 or
1747ĆKE device.
[F2] Parity
Toggles between None and Even. The default selection is
None.
[F3] Error Check
Toggles between Cyclic Redundancy Check (CRC) and Block
Check Character (BCC) error checking procedures. The
default selection is CRC.
[F4] Use Modem
Toggles between Yes and No. This field indicates if a modem
is being used. If a modem is used the KF3/KE must have flow
control enabled for handshaking. If No is selected, flow control
is disabled and function keys [F5], [F6], and [F8] are inactive.
If you use a modem, you must enter at least one telephone
number to establish communication. The default selection is
Yes.
[F5] Dial Phone Number
➀
Toggles between Yes, No, Yes-And Always Send Init
String,and No-But Always Send Init String. If set to Yes or
YesĆAnd Always Send Init String, the telephone number is
dialed. If set to No or No-But Always Send Init String, a direct
connection is made. The default selection is Yes.