Offline config – Rockwell Automation 9323-PA1E USER MANUAL APS 6.0 User Manual
Page 161

Protection
8–19
3.
If you want to write protect your memory module permanently, press
CONFIG
OFFLINE
CONFIG
WRITE
PROTECT
F8
. The prompt line changes to the following:
FILE
PROTECTED
NAME
TYPE
SIZE (words)
0
system
76
1
reserved
0
2
Yes
ladder
6
WARNING, SELECTING YES DISABLES FUTURE REPROGRAMMING OF MEMORY MODULE
Press F8 to write-protect memory module.
REM RUN
L532 Series C Rev.2
PROC Addr 1
PROGRAM DIRECTORY FOR PROCESSOR: TOGGLE
F10
NO
F8
YES
4.
Confirm the transfer by pressing
CONFIG
OFFLINE
CONFIG
YES
F8
. While the transfer takes place the
prompt
...WORKING...
is displayed. If the transfer is successful the
program directory for the processor is displayed.
Press
CONFIG
OFFLINE
CONFIG
NO
F10
to cancel the transfer and return to the previous display.
5.
If you want to reuse the memory module, press
CONFIG
OFFLINE
CONFIG
ALLOW
REUSE
F10
and confirm your
choice by pressing
CONFIG
OFFLINE
CONFIG
YES
F8
. Press
[ESC]
or
CONFIG
OFFLINE
CONFIG
NO
F10
to cancel the
transfer.
If you choose to write protect a memory module and then later decide to erase the
protected data, you must use a commercially available PROM burner. The SLC
5/03 and SLC 5/04 processor memory modules use “Flash EEPROM” technology.
A memory module is erased when its contents consist of all zeros or all ones.
- 20P PowerFlex DC Drive - Frame D Bimetal Thermostat (10 pages)
- 1336S_F_T_E_R F Frame Snubber Resistor Repl. (6 pages)
- 22-COMM PowerFlex 4-Class DSI (Drive Serial Interface) Network Communication Adapter (4 pages)
- 8-545 Plug In Solid State Relay (2 pages)
- 20-HIM-B1 PowerFlex 7-Class HIM Bezel (DPI) (4 pages)
- 100 Contactors with DC Coil (2 pages)
- 100 Contactors with DC Coil (1 page)
- 20P PowerFlex DC Drive - Frame D Switching Power Supply Circuit Board (6 pages)
- 140G-MTFx_MTHx_MTIx_MTKx Trip Unit Installation-140G-M (6 pages)
- 45BRD Analog Laser Sensor (4 pages)
- 20D Multi-Device Interface Option Board for PowerFlex 700S Drives (20 pages)
- 56RF RFID 18 mm Cylindrical Transceiver (2 pages)
- 42KC Miniature Rectangular: 5V DC Version (2 pages)
- 20P PowerFlex DC Drive - Frame A Switching Power Supply Circuit Board (16 pages)
- 21P-MISC-A-TP-2 Transition Tube Kit #C19-6/7 For PowerFlex 755 w/OEM Liquid Cooling Fr 6/7 Drive (2 pages)
- 42BT Background Suppression Sensor (3 pages)
- 42CB High Speed 18mm Cylindrical (4 pages)
- 140EX-JE2_JE3 Molded Case Circuit Breaker (4 pages)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (1 page)
- 140G-K-EAM1A Early Make Aux Contact for Rotary Handle Oper Mech-140G-K (3 pages)
- 20-HIM-A6 PowerFlex (Human Interface Module) (74 pages)
- 42CF General Purpose 12mm Cylindrical (4 pages)
- 20D PowerFlex 700S Phase II Drive Frames 1...6 (80 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (6 pages)
- 140EX-HE1_HE2 Molded Case Circuit Breaker (4 pages)
- 20B PowerFlex 700 Custom Firmware - Pump Off (12 pages)
- 20-WIM-N4S DPI Wireless Interface Module (92 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (2 pages)
- 140U H-Frame Circuit Breaker Fixed and Adjustable Thermal Trip (7 pages)
- 60-2619, 42JS Swivel/Tilt Mounting Bracket (1 page)
- 22A PowerFlex 4/40/400 Flange Mount (4 pages)
- 45MLA Controller Installation Instructions (16 pages)
- 20P PowerFlex DC Drive - Cooling Fan for Frame A Drives Above 73A at 230V 460V AC (6 pages)
- 42JS Series 7000 to 42JS VisiSight Replacement Kit (2 pages)
- 22A PowerFlex 4-Class HIM Bezel (DSI) (4 pages)
- 42CS Stainless Steel Photoelectric Sensors (4 pages)
- 20L-LL PowerFlex 700L Liquid-to-Liquid Heat Exchanger (40 pages)
- 20P PowerFlex DC Drive - Frame B SCR Modules (20 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (161 pages)
- 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx (22 pages)
- 22F PowerFlex 4M Input RFI Filters (2 pages)
- 45LFM Capacitive Label Sensor (4 pages)
- 140G-Rx Installation Instruction-140G-R (29 pages)
- 140G-Rx Installation Instruction-140G-R (2 pages)
- 22C PowerFlex 400 AC Drive Quick Start - FRN 1-4.xx (28 pages)