Use the no form of the TIMERS BASIC command to restore the default
values to the timers.

Command Mode

Router mode

Example

The following commands set the UPDATE timer to 30 seconds, TIMEOUT
timer to 180 seconds, and the GARBAGE timer 120 seconds:

switch#configure terminal

switch(config)#router rip

switch(config-router)#timers basic 30 180 120

Related Commands