Snmp-server enable traps environ – Allied Telesis AT-S83 User Manual
Page 159

AT-S83 Management Software Command Line Interface User’s Guide
159
SNMP-SERVER ENABLE TRAPS ENVIRON
Syntax
snmp-server enable traps environ fan|volt|temp
no snmp-server enable traps environ fan|volt|temp
Parameters
environ
Specifies the environment of the trap. Choose from the
following options:
fan
Indicates a trap is set when the fan speed is less
than 3,800 Revolutions Per Minute (RPM) or greater
than 6,350 RPM.
volt
Indicates a trap is set when the voltage level is less
than 0.94 volts or greater than 12.75 volts.
temp Indicates a trap is set when the temperature of the
switch exceeds 60° C.
Description
Use the SERVER ENABLE TRAPS ENVIRON command to enable
environmental traps to a host. You must enable each environmental trap
individually. For example, to set traps on the fan and the power supply you
must enter two commands.
Use the no form of this command to disable SNMP environment traps. You
can disable SNMP environment traps individually or all at once.
Command Mode
Configuration Terminal mode
Examples
The following command sets a trap on the fan:
switch#snmp-server enable traps environ fan
The following command sets a trap on the voltage level:
switch#snmp-server enable traps environ volt
The following command disables all of the SNMP environmental traps:
switch#no snmp-server disable traps environ