DOT1X TIMEOUT SUPP-TIMEOUT

Syntax

dot1x timeout supp-timeout

SECS <1-65535>

no dot1x timeout supp-timeout

Parameters

SECS

Specifies the supplicant response timeout. The default

timeout is 30 seconds. The range is from 1 to 65,535
seconds.

Description

Use the DOT1X TIMEOUT SUPP-TIMEOUT command to set the interval
for a supplicant to respond. Use the no form of this command to return it to
the default setting.

Command Mode

Interface mode

Example

The following commands set the supplicant timeout to 40 seconds on
interface 2.

switch# configure terminal

switch(config)# interface xe2

switch(config-if)# dot1x timeout supp-timeout 40

Related Commands