5 connection of pulse train signal – IAI America SCON-CA User Manual
Page 82
Chapter 2 Wiring
72
2.3.5 Connection of Pulse Train Signal
Only the plug and the shell are equipped for the standard type.
Perform the same cable layout as the optional connector cable for the pulse train control.
[1] Standard Type (Plug + Shell)
The plug and shell are standard accessory.
Plug : 10114-3000PE (Supplier : 3M)
Shell : 10314-52F0-008 (Supplier : 3M)
The assignment of the signal is the same as [2] Cable for Pulse Control in Option. Refer to
that to perform the connection.
Use the multiple twisted pair shielded cable with AWG24 (0.2mm
2
). When using the cables of
the host controller (PLC, etc.), solder it directly to the connector.
Also, to prevent the noise influence as much as possible, make the cable as short as
possible.
[2] Cable with Connectors for Pulse Train Control (Option)
Model : CB-SC-PIOS��� ��� indicates the cable length Example) 020 = 2m
Cable length : 10m MAX. in differential mode
2m MAX. in open collector mode
Note : There is no connector equipped on the host controller (PLC, etc.) side. Make
an appropriate treatment that suits the host controller (PLC, etc.). Also, to
prevent the noise influence as much as possible, make the cable as short as
possible.
Pin No. 1
Pin No. 8
Plug
Shell
10114-3000PE (Sumitomo 3M)
10314-52F0-008 (Sumitomo 3M)
:
:
CB-SC-PIOS***
Host System Side
AWG24
(0.2mm
2
)
Soldered
Wiring
Color
BK
WT/BK
RD
WT/RD
GN
WT/GN
YW
WT/YW
BR
WT/BR
BL
WT/BL
GY
WT/GY
Symbol
Signal Name
Pulse Train Input
Line Driver Output Line for
Feedback Pulse Output
Shield is connected to the cable clamp
Shield