4 alarm list – IAI America SCON-CA User Manual
Page 256
Chapter 9
Troubleshooting
246
9.4 Alarm List
Alarm
Code
Alarm
Level
Alarm Name
Cause/Treatment
02E
Calendar function related
command in calendar
function invalid status
Cause
: An attempt was made to use the calendar in the
state where the RTC (calendar) function was made
ineffective.
Treatment : Set parameter No.111 (Selection of use of calendar
function) to “1” (“0”: no use).
048
Driver Overload Alarm
Cause
: The load current exceeded the value set in
Parameter No.143 “Overload Level Ratio”.
This alarm is kept alarm condition until reset is
made. This alarm turns ON when the load current
exceeds the setting from a value below the setting.
Treatment : Lower the setting of acceleration/deceleration. Also,
increase the frequency of pause.
04E
Exceeded movement
count threshold
Cause
: The total number of the operation times exceeded
the value set in Parameter No.147 “Total Movement
Count Threshold”.
04F
Exceeded operated
distance threshold
Cause
: The total number of the operation distance
exceeded the value set in Parameter No.148 “Total
Operated Distance Threshold”.
068
SRAM access error
Cause
: Servo monitor is not operated in the normal
condition because of noise or malfunction of
consisting parts.
Treatment : 1) Take proper measures against noise.
2) When the servo monitoring function is not used,
set parameter No.112 “Monitoring mode” to “0”.
3) If the operation is not improved in use of the
servo monitoring function in spite of measures
against noise, Please contact IAI.
069
Detection of realtime clock
oscillation stop
Cause
: The calendar function is stopped and the current
time data is lost.
Treatment : Set the time again.
[Refer to the Instruction Manual of RC PC software.]
(Note) This error is not registered in the alarm list.
06A
Realtime clock access
error
Cause
: The calendar function is not working properly
because of noise or malfunction of consisting parts.
Treatment : 1) Take proper measures against noise.
2) When the calendar function is not used, set
parameter No.111 “Calendar function” to “0”.
3) If the operation is not improved in use of the
calendar function in spite of measures against
noise, Please contact IAI.
06B
Message
Maintenance information
data error
Cause
: The maintenance information (total movement
count, total operated distance) is lost.
Treatment : Please contact IAI.