Rcb-lb-tg, Chapter 10 appendix, Motor power supply – IAI America SCON-CA User Manual
Page 276
Chapter 10
Appendix
266
3) In case of category 3 or 4
CON-TG
(or Dummy plug: DP-4)
Connection Cable CB-CON-LB***
Controller
● SCON
ENBOUT
ENBIN
ENB2+
ENB2-
ENB1+
ENB1-
EMGOUT
EMGIN
EMG2+
EMG2-
EMG1+
EMG1-
RCB-LB-TG
Motor
Power
Supply
Motor Power Supply
SCON : 100V AC/200V AC
12
11
10
9
8
7
6
5
4
3
2
1
Solenoid Contactor Solenoid Contactor
Enable SW
Reset SW
Emergency Stop SW
Emergency Stop SW
For Category 4, insert
Reset Switch as shown
in the diagram.
For Category 3, layout
the wiring without
inserting Reset Switch.
For Category 4, make
the connection of A
and B open.
For category 3, make
a short circuit
between A and B.
See also other documents in the category IAI America Hardware:
- ERC2 (138 pages)
- ERC2 (188 pages)
- ERC3 (438 pages)
- ERC (153 pages)
- RCA-E (53 pages)
- RCA-P (42 pages)
- RCB-101-MW (38 pages)
- RCP2-C (178 pages)
- RCS-E (102 pages)
- RCA-A4R (72 pages)
- RCA-RA3C (114 pages)
- RCA-SRA4R (56 pages)
- RCA2-RA2AC (100 pages)
- RCA2-SA2AC (92 pages)
- RCA2-TA4C (134 pages)
- RCD-RA1D (40 pages)
- RCP2-BA6 (72 pages)
- RCP2-GRSS (130 pages)
- RCP2-HS8C (126 pages)
- RCP2-RA2C (120 pages)
- RCP2-RTBS (80 pages)
- RCP2W-SA16C (46 pages)
- RCP3-RA2AC (60 pages)
- RCP4-RA5C (82 pages)
- RCP4-SA5C (94 pages)
- RCP4W (96 pages)
- RCS2-F5D (142 pages)
- RCS2-GR8 (46 pages)
- RCS2-RN5N (80 pages)
- RCS2-RT6 (60 pages)
- RCS2-SA4C (258 pages)
- RCS2-TCA5N (62 pages)
- RCL-SA1L (66 pages)
- RCL-RA1L (56 pages)
- RCLE-GR5L (46 pages)
- IK Series (16 pages)
- FS (84 pages)
- IF (76 pages)
- ISB (114 pages)
- ISDA (126 pages)
- ISDB (116 pages)
- ISPWA (90 pages)
- ICS(P)A (16 pages)
- NS (78 pages)
- RS (46 pages)