Chapter 2 wiring – IAI America SCON-CA User Manual
Page 62
Chapter 2 Wiring
52
5) PIO Pattern 4 ·················Solenoid Valve Mode 1 (7-point type)
0V(NPN Type)
24V DC
Supply
1A
P24
PE0
1B
0V
Supply
24V DC(NPN Type)
24V DC(PNP Type)
2A
P24
PE1
2B
0V(PNP Type)
Start Signal 0
Start Signal 5
Start Signal 6
Start Signal 4
Start Signal 3
Start Signal 2
Start Signal 1
3A
ST0
PE2
3B
Current Position No.0
Current Position No.2
Current Position No.1
Current Position No.3
Current Position No.4
Current Position No.5
Current Position No.6
4A
ST2
ST1
PE3
4B
5A
ST3
PE4
5B
6A
ST4
PE5
6B
7A
ST5
PE6
7B
8A
ST6
ZONE1
8B
9A
BKRL
9B
10A
RMOD
RMDS
10B
11A
HOME
HEND
11B
12A
*STP
PEND
12B
13A
SV
13B
14A
RES
*EMGS
14B
15A
SON
*ALM
*BALM
15B
16A
16B
17A
N
17B
18A
N
18B
19A
19B
20A
20B
SCON
PIO
Connector
BR- 1
RD- 1
OR- 1
YW- 1
GN- 1
BL- 1
PL- 1
GY- 1
WT- 1
BK- 1
BR- 2
RD- 2
OR- 2
YW- 2
GN- 2
BL- 2
PL- 2
GY- 2
WT- 2
BK- 2
BR- 3
RD- 3
OR- 3
YW- 3
GN- 3
BL- 3
PL- 3
GY- 3
WT- 3
BK- 3
BR- 4
RD- 4
OR- 4
YW- 4
GN- 4
BL- 4
PL- 4
GY- 4
WT- 4
BK- 4
Brake Control Release
Operation Mode Changeover
Home Return
Pause
Reset
Servo ON
Zone
Operating Mode Status (Manual Mode)
Home Return Completion
Position Completion
Servo ON Status
Emergency Stop Status
Alarm
Absolute Battery
Voltage Drop Warning Output
Position Zone/Zone 2
PZONE
/ZONE2
“*” in codes above shows the signal of the active low. Processing occurs when an
input signal of the type is turned OFF. An output signal of the type is normally ON
in the power-on status and turned OFF at signal output.
�� Use the attached cable for the I/O connection.
Model : CB-PAC-PIO��� (��� indicates the cable length L. Example. 020 = 2m)
Half Pitch MIL Socket
HIF6-40D-1.27R (Hirose Electric)
Flat Cable (20-core) × 2
L
20A
20B
1A
1B
BK -4 (20B)
BK -2 (20A)
BR -3 (1B)
BR -1 (1A)
No connector
No connector