beautypg.com

Chapter 2 wiring – IAI America SCON-CA User Manual

Page 50

background image

Chapter 2 Wiring

40

(2)� PIO Patterns and Signal Assignment

The signal assignment of I/O flat cable by the PIO pattern is as shown below. Follow the

following table to connect the external equipment (such as PLC).

Parameter No.25 (PIO Pattern) Selection

0

1

2

3

Category

PIO Functions

Positioning Mode

Teaching mode

256-point mode 512-point mode

Number of positioning

points

64 points

64 points

256 points

512 points

Home return signal

Jog Signal

Teaching Signal

(Current Position

Writing)

Input

Brake Release

Moving Signal

Zone Signal

(�)

(Note1)

(�)

(Note1)

Pin

No.

Output

Position zone signal

1A

24V

P24

2A

24V

P24

3A

4A

5A

IN0

PC1

PC1

PC1

PC1

6A

IN1

PC2

PC2

PC2

PC2

7A

IN2

PC4

PC4

PC4

PC4

8A

IN3

PC8

PC8

PC8

PC8

9A

IN4

PC16

PC16

PC16

PC16

10A

IN5

PC32

PC32

PC32

PC32

11A

IN6

MODE

PC64

PC64

12A

IN7

JISL

PC128

P128

13A

IN8

JOG+

PC256

14A

IN9

BKRL

JOG-

BKRL

BKRL

15A

IN10

RMOD

RMOD

RMOD

RMOD

16A

IN11

HOME

HOME

HOME

HOME

17A

IN12

*STP

*STP

*STP

*STP

18A

IN13

CSTR

CSTR/PWRT

CSTR

CSTR

19A

IN14

RES

RES

RES

RES

20A

Input

IN15

SON

SON

SON

SON

1B

OUT0

PM1

PM1

PM1

PM1

2B

OUT1

PM2

PM2

PM2

PM2

3B

OUT2

PM4

PM4

PM4

PM4

4B

OUT3

PM8

PM8

PM8

PM8

5B

OUT4

PM16

PM16

PM16

PM16

6B

OUT5

PM32

PM32

PM32

PM32

7B

OUT6

MOVE

MOVE

PM64

PM64

8B

OUT7

ZONE1

MODES

PM128

PM128

9B

OUT8

(Note1)

PZONE/ZONE2

PZONE/ZONE1

PZONE/ZONE1

PM256

10B

OUT9

RMDS

RMDS

RMDS

RMDS

11B

OUT10

HEND

HEND

HEND

HEND

12B

OUT11

PEND

PEND/WEND

PEND

PEND

13B

OUT12

SV

SV

SV

SV

14B

OUT13

*EMGS

*EMGS

*EMGS

*EMGS

15B

OUT14

*ALM

*ALM

*ALM

*ALM

16B

Output

OUT15

*BALM

*BALM

*BALM

*BALM

17B

18B

19B

0V

N

20B

0V

N

(Note) “*” in codes above shows the signal of the active low.

PM1 to PM8 indicate the alarm binary code output signal when an alarm is generated. [Refer to 3.2.3 [7] Binary

Alarm]

(Note 1) PZONE can be switched over to ZONE with the setting of Parameter No.149 except for PIO Pattern 3.

(Reference) Signal of Active Low

Signal with “*” expresses the signal of active low. A signal of active low is a signal that the input

signal is processed when it is turned OFF, output signal is ordinary on while the power is ON,

and turns OFF when the signal is output.