2 i/o signals in pulse train control mode, Chapter 2 wiring – IAI America SCON-CA User Manual
Page 69
Chapter 2 Wiring
59
2.2.2 I/O Signals in Pulse Train Control Mode
The table below shows the signal assignment of the flat cable in the pulse train control mode.
Follow the following table to connect the external equipment (such as PLC).
Pin
No. Category I/O No.
Signal
Abbreviation
Signal Name
Function Description
Relevant
Sections
1A
24V
P24
Power Supply
Power Supply for I/O +24V
2A
24V
P24
Power Supply
Power Supply for I/O +24V
3A
–
NC
–
Not used
4A
–
NC
–
Not used
5A
IN0
SON
Servo ON
The servo remains ON while this signal is ON, or OFF
while this signal is OFF.
3.3.2
6A
IN1
RES
Reset
Turn the signal ON to reset the alarm.
3.3.2
7A
IN2
HOME
Home Return
The controller will perform home return operation when
this signal is turned ON.
3.3.2
8A
IN3
TL
Torque Limit Select Puts torque limitation to the motor with the signal ON and
the value set to the parameter.
3.3.3
9A
IN4
CSTP
Compulsory Stop
Turning it ON continuously for more than 10ms
compulsorily stops the actuator.
The actuator decelerates then stops with the torque set in
the controller and then turns the servo OFF.
3.3.2
10A
IN5
DCLR
Deviation Counter
Clear
Clears the deviation counter.
3.3.3
11A
IN6
BKRL
Brake Forcible
Release
The brake will forcibly be released.
3.3.2
12A
IN7
RMOD
Operation Mode
Changeover
The operating mode is selectable when the MODE switch
of the controller is set to AUTO.
(The setting is AUTO when signal is OFF, and MANU
when ON.)
3.3.2
13A
IN8
NC
–
Not used
14A
IN9
NC
–
Not used
15A
IN10
NC
–
Not used
16A
IN11
NC
–
Not used
17A
IN12
NC
–
Not used
18A
IN13
NC
–
Not used
19A
IN14
NC
–
Not used
20A
Input
IN15
NC
–
Not used
1B
OUT0
PWR
System Ready
This signal turns ON if SCON is controllable after main
power ON.
3.3.2
2B
OUT1
SV
Servo ON Status
This signal will remain ON while the servo is ON.
3.3.2
3B
OUT2
INP
Position Complete
Turned ON when the remaining moving pulses in the
deviation counter enters within the positioning band.
3.3.3
4B
OUT3
HEND
Home return
completion
This signal will turn ON when home return has been
completed.
3.3.2
5B
OUT4
TLR
Torque Under
Control
Turns ON if the torque reaches the limit value during
torque limit.
3.3.3
6B
OUT5
*ALM
Controller Alarm
Status
Turns ON when controller in normal condition, and OFF
when alarm is generated.
3.3.2
7B
OUT6
*EMGS
Emergency Stop
Status
Turns ON when the controller emergency stop is
cancelled, and OFF during the emergency stop.
3.3.2
8B
OUT7
RMDS
Operation Mode
Status
The operating mode status will be output. It turns ON
when the controller is on Manual Mode.
3.3.2
9B
OUT8
ALM1
10B
OUT9
ALM2
11B
OUT10
ALM4
12B
OUT11
ALM8
Alarm Code Output
Signal
The alarm code is output together with the alarm signal
output.
Refer to Alarm List for details.
3.3.2
13B
OUT12
*OVLW/
*ALML
Overload Alarm/
Light Error Alarm
Turns OFF if exceeded the overload warning threshold
(set in Parameter No.143) when Parameter No.151 is set
to 0 (Overload Warning).
It turns OFF when the message level alarm is generated
if Parameter No.151 is set to 1 (Light Error Alarm).
3.3.2
14B
OUT13
NC
–
Not used
15B
OUT14
ZONE1
Zone Signal 1
16B
Output
OUT15
ZONE2
Zone Signal 2
This signal will turn ON when the current actuator position
enters the range set by the parameters.
3.3.2
17B
–
NC
–
Not used
18B
–
NC
–
Not used
19B
0V
N
Power Supply
Power Supply for I/O 0V
20B
0V
N
Power Supply
Power Supply for I/O 0V
Signal with “*” expresses the signal of active low. It is ON when the power is applied to the controller, and
turns OFF when the signal is output.