Chapter 2 Wiring

59

2.2.2 I/O Signals in Pulse Train Control Mode

The table below shows the signal assignment of the flat cable in the pulse train control mode.

Follow the following table to connect the external equipment (such as PLC).

Pin

No. Category I/O No.

Signal

Abbreviation

Signal Name

Function Description

Relevant

Sections

1A

24V

P24

Power Supply

Power Supply for I/O +24V

2A

24V

P24

Power Supply

Power Supply for I/O +24V

3A

NC

Not used

4A

NC

Not used

5A

IN0

SON

Servo ON

The servo remains ON while this signal is ON, or OFF

while this signal is OFF.

3.3.2

6A

IN1

RES

Reset

Turn the signal ON to reset the alarm.

3.3.2

7A

IN2

HOME

Home Return

The controller will perform home return operation when

this signal is turned ON.

3.3.2

8A

IN3

TL

Torque Limit Select Puts torque limitation to the motor with the signal ON and

the value set to the parameter.

3.3.3

9A

IN4

CSTP

Compulsory Stop

Turning it ON continuously for more than 10ms

compulsorily stops the actuator.

The actuator decelerates then stops with the torque set in

the controller and then turns the servo OFF.

3.3.2

10A

IN5

DCLR

Deviation Counter

Clear

Clears the deviation counter.

3.3.3

11A

IN6

BKRL

Brake Forcible

Release

The brake will forcibly be released.

3.3.2

12A

IN7

RMOD

Operation Mode

Changeover

The operating mode is selectable when the MODE switch

of the controller is set to AUTO.

(The setting is AUTO when signal is OFF, and MANU

when ON.)

3.3.2

13A

IN8

NC

Not used

14A

IN9

NC

Not used

15A

IN10

NC

Not used

16A

IN11

NC

Not used

17A

IN12

NC

Not used

18A

IN13

NC

Not used

19A

IN14

NC

Not used

20A

Input

IN15

NC

Not used

1B

OUT0

PWR

System Ready

This signal turns ON if SCON is controllable after main

power ON.

3.3.2

2B

OUT1

SV

Servo ON Status

This signal will remain ON while the servo is ON.

3.3.2

3B

OUT2

INP

Position Complete

Turned ON when the remaining moving pulses in the

deviation counter enters within the positioning band.

3.3.3

4B

OUT3

HEND

Home return

completion

This signal will turn ON when home return has been

completed.

3.3.2

5B

OUT4

TLR

Torque Under

Control

Turns ON if the torque reaches the limit value during

torque limit.

3.3.3

6B

OUT5

*ALM

Controller Alarm

Status

Turns ON when controller in normal condition, and OFF

when alarm is generated.

3.3.2

7B

OUT6

*EMGS

Emergency Stop

Status

Turns ON when the controller emergency stop is

cancelled, and OFF during the emergency stop.

3.3.2

8B

OUT7

RMDS

Operation Mode

Status

The operating mode status will be output. It turns ON

when the controller is on Manual Mode.

3.3.2

9B

OUT8

ALM1

10B

OUT9

ALM2

11B

OUT10

ALM4

12B

OUT11

ALM8

Alarm Code Output

Signal

The alarm code is output together with the alarm signal

output.

Refer to Alarm List for details.

3.3.2

13B

OUT12

*OVLW/

*ALML

Overload Alarm/

Light Error Alarm

Turns OFF if exceeded the overload warning threshold

(set in Parameter No.143) when Parameter No.151 is set

to 0 (Overload Warning).

It turns OFF when the message level alarm is generated

if Parameter No.151 is set to 1 (Light Error Alarm).

3.3.2

14B

OUT13

NC

Not used

15B

OUT14

ZONE1

Zone Signal 1

16B

Output

OUT15

ZONE2

Zone Signal 2

This signal will turn ON when the current actuator position

enters the range set by the parameters.

3.3.2

17B

NC

Not used

18B

NC

Not used

19B

0V

N

Power Supply

Power Supply for I/O 0V

20B

0V

N

Power Supply

Power Supply for I/O 0V

Signal with “*” expresses the signal of active low. It is ON when the power is applied to the controller, and

turns OFF when the signal is output.