Chapter 2 wiring – IAI America SCON-CA User Manual
Page 59
Chapter 2 Wiring
49
2) PIO Pattern 1 ···············Teaching mode (Teaching type)
Position Zone/Zone 1
0V(NPN Type)
24V DC
Supply
1A
P24
PM1
1B
0V
Supply
24V DC(NPN Type)
24V DC(PNP Type)
2A
P24
PM2
2B
0V(PNP Type)
Command Position No.1
3A
PC1
PM4
3B
Completed Position No.1
Command Position No.2
4A
PC2
PM8
4B
Completed Position No.2
Command Position No.4
5A
PC4
PM16
5B
Completed Position No.4
Command Position No.8
6A
PC8
PM32
6B
Completed Position No.8
Command Position No.16
7A
PC16
MOVE
7B
Completed Position No.16
Command Position No.32
8A
PC32
MODE
MODES
8B
Completed Position No.32
Jog Move -
9A
JOG-
JOG+
JISL
9B
Moving
Operation Mode Changeover
10A
RMOD
RMDS
10B
Teaching Mode Status
Home Return
Teaching Mode
Jog/inching Changeover
Jog Move +
11A
HOME
HEND
11B
Pause
12A
*STP
PEND/WEND
12B
Operating Mode Status (Manual Mode)
13A
CSTR/PWRT
SV
13B
Home Return Completion
Reset
14A
RES
*EMGS
14B
Position Writing Completion
Servo ON
15A
SON
*ALM
*BALM
15B
Servo ON Status
16A
16B
Emergency Stop Status
17A
N
17B
Alarm
18A
N
18B
Absolute Battery
Voltage Drop Warning Output
19A
19B
20A
20B
SCON
PIO
Connector
BR- 1
RD- 1
OR- 1
YW- 1
GN- 1
BL- 1
PL- 1
GY- 1
WT- 1
BK- 1
BR- 2
RD- 2
OR- 2
YW- 2
GN- 2
BL- 2
PL- 2
GY- 2
WT- 2
BK- 2
BR- 3
RD- 3
OR- 3
YW- 3
GN- 3
BL- 3
PL- 3
GY- 3
WT- 3
BK- 3
BR- 4
RD- 4
OR- 4
YW- 4
GN- 4
BL- 4
PL- 4
GY- 4
WT- 4
BK- 4
PZONE
/ZONE1
�
“*” in codes above shows the signal of the active low. Processing occurs when an
input signal of the type is turned OFF. An output signal of the type is normally ON
in the power-on status and turned OFF at signal output.
�� Use the attached cable for the I/O connection.
Model : CB-PAC-PIO��� (��� indicates the cable length L. Example. 020 = 2m)
Half Pitch MIL Socket
HIF6-40D-1.27R (Hirose Electric)
Flat Cable (20-core) × 2
L
20A
20B
1A
1B
BK -4 (20B)
BK -2 (20A)
BR -3 (1B)
BR -1 (1A)
No connector
No connector