Chapter 3 Operation

128

� �

Caution: (1) The speed during pressing operation is set in Parameter No.34. Check the

10.4 List of Specifications of Connectable Actuators for the pressing

operation speed.

Do not set any value larger than the value in the list. If the speed set in the

position table is equal to or less than the pressing speed, the pressing is

performed at the setup speed.

(2) The approach start position of pressing should be located at or before the

pressing start position (coordinate 100mm or less in the above example) If

not, the moving direction varies depending on the start position to be

dangerous.

For example, if the pressing operation is conducted from a coordinate value

above the pressing complete position (above 150mm), it will become the

tension operation from the current point to the pressing complete position.

Please note that it cannot be the pressing operation to the point of 150mm

after the positioning at the point of 100mm.

(3) The work is pressed after the pressing is completed. The work may moves

backward or forward. If the actuator is moved backward before the

approach position, alarm code 0DC “Pressing Motion Range Over Error”

occurs to stop the actuator. In movement of the work in the pressing

direction, PEND is turned OFF if the load current becomes lower than the

current limit (pressing (%)). Miss-pressing occurs when the actuator moves

by the pressing moving distance set in “Positioning width”. Current Position

No. PE* keeps turned on until the next movement command is made even if

the work piece gets moved and pushed backward or goes further forward

once it is turned on at the pressing operation complete.

(4) Pressing operation cannot be performed with the rotary actuator.

(5) If the actuator is RCS2-RA13R (Ultra-High Thrust Type), there is a limit in

the duration and duty of continuous pressing. Use of the product above this

limit may cause a failure occurred due to the motor heat generation.

[Refer to 10.4.2 Specifications and Limitations in Pressing Operation of

RCS2-RA13R]

Positioning Completion Signal

PEND

(Controller�PLC)

Turned OFF by

turning PEND ON

Turned on even

in miss-pressing

Start signal

ST*

(PLC�Controller)

Current Position No.

PE*

(Controller�PLC)

Not turned ON for

miss-pressing

Pressing

operation

Pressing

Completion

Operation of actuator

Approach operation

Positioning be setting

of coordinate Value

Movement by

positioning

width

Stop of

presasing

Pressing start position

100mm

Pressing end position

100 + 50 = 150mm

ST*

Pressing operation

ST*

Approach operation

ST*:Start position

ST*

Pressing operation

Tension operation