3 wiring method, 1 wiring of power circuit – IAI America SCON-CA User Manual
Page 76
Chapter 2 Wiring
66
2.3
Wiring Method
2.3.1 Wiring of Power Circuit
Supply the appropriate power from the following considering the controller type.
Power Supply Type
Specifications
Reference
Motor Power Supply
Control Power Supply
100V Specification : 100 to 115V AC �10% 50/60Hz
200V Specification : 200 to 230V AC �10% 50/60Hz
I/O Power Supply
24V DC �10%
When the PIO is used
Brake Power Supply 24V DC �10% 1A
For brake equipped type
The figure below shows a sample wiring of the power circuit.
�
L1
L2
L1C
L2C
NC
PE
Circuit
Breaker
Ground Fault
Circuit
Interrupter
1) Noise
Filter
2) Clamp Filter
3) Surge Protector
SCON
100V AC
or
200V AC
P
W
R
-
B
K
+
+24V
0V
Brake Power Supply
Input Connector
AC Power Supply
Input Connector
PIO Connector
A. Control Power Supply
B. Motor Power Unit
24V DC
Power
Supply
Brake
Release Box
�
Caution : Attaching noise filter 1) is a mandatory thing to do. Not doing so may cause
error or unexpected operation to the controller because of noise.
Also, the peripheral devices may receive an influence of this controller noise.
Attach 2) and 3) if necessary considering the noise environment and the power
supply condition. It is recommended to attach them even though it is not
mandatory.
Load current of SCON-CA varies depending on the connected actuator, etc. Select the circuit
breaker that suits to the specification.
[Refer to 1.3]
Parts Name
Model
Supplier
Position to attach
NF2010A-UP
SOSHIN ELECTRIC
CO.,LTD
1) Noise Filter
MC1210
DENSEI-LAMBDA
Attach in range of
300mm or less from
controller
2) Clamp Filter
ZCAT3035-1330
TDK
Attach as close as
possible to controller
3)
Surge
Protector R • A • V-781BWZ-2A
Okaya ELECTRIC
CO.,LTD
Attach at the input
terminal of noise filter
�