IAI America SCON-CA User Manual
Page 190
Chapter 5 V
ibration Suppress Control Function
180
5.2 Settings of Parameters for Vibration Suppress Control
Set the parameters associated with vibration suppress control, which are listed in the table
below.
Parameter
No.
Parameter
Set No.
Parameter Name
Unit
Factory
Setting
Input Range
97
Damping characteristic
coefficient 1
Rate
10
0 to 1000
98
Damping characteristic
coefficient 2
Rate
1000
0 to 1000
99
Natural frequency
1/1000Hz
10000
500 to 30000
100
1
Notch filter gain
Rate
9990
1 to 20000
101
Damping characteristic
coefficient 1
Rate
10
0 to 1000
102
Damping characteristic
coefficient 2
Rate
1000
0 to 1000
103
Natural frequency
1/1000Hz
10000
500 to 30000
104
2
Notch filter gain
Rate
9990
1 to 20000
105
Damping characteristic
coefficient 1
Rate
10
0 to 1000
106
Damping characteristic
coefficient 2
Rate
1000
0 to 1000
107
Natural frequency
1/1000Hz
10000
500 to 30000
108
3
Notch filter gain
Rate
9990
1 to 20000
109
Default vibration suppress No.
0
0 to 3
110
Stop method at servo OFF
0
0, 1
[1] Damping characteristic coefficient 1,2 (Parameter No.97, 98, 101, 102, 105, and 106)
Do not change.
[2] Natural frequency [1/1000Hz] (Parameter No.99, 103 and 107)
Set the natural frequency of the load measured. It can be input directly to the parameter
from the frequency analysis tool for anti-vibration control included in the PC software if the
tool is already used. [Refer to the Instruction Manual of the PC software.]
Set the specific frequency of the loaded object close to the setting so a higher anti-vibration
performance can be obtained.
[Reference] Other vibration measuring methods
�
Use of measuring instrument such as vibration meter and acceleration
pickup
�
Calculation from video image data
[3] Notch filter gain (Parameter No.100, 104 and 108)
Set the notch filter gain following the table below in response to the measured specific
frequency of the loaded object. See the table below for reference. Provide fine adjustment if
overshooting occurs.
If the notch filter gain setting is too high, overshooting would occur during the settling time.
If the notch filter gain setting is too low, undershooting would occur during the settling time.
Setting Value of Notch Filter Gain
Measured Natural
Frequency [Hz]
Other than linear actuator
Linear actuator
0.5
9900
9880
1
9980
9970
2 to 30
9990
9990
�