5] pio circuit, Chapter 2 wiring – IAI America SCON-CA User Manual
Page 58
Chapter 2 Wiring
48
[5] PIO Circuit
�
1) PIO Pattern 0 ···············Positioning Mode (Standard Type)
0V(NPN Type)
24V DC
Supply
BR- 1
1A
P24
PM1
1B
BR- 3
0V
Supply
24V DC(NPN Type)
24V DC(PNP Type)
RD- 1
2A
P24
PM2
2B
RD- 3
0V(PNP Type)
Command Position No.1
OR- 1
3A
PC1
PM4
3B
OR- 3
Completed Position No.1
Command Position No.2
YW- 1
4A
PC2
PM8
4B
YW- 3
Completed Position No.2
Command Position No.4
GN- 1
5A
PC4
PM16
5B
GN- 3
Completed Position No.4
Command Position No.8
BL- 1
6A
PC8
PM32
6B
BL- 3
Completed Position No.8
Command Position No.16
PL- 1
7A
PC16
MOVE
7B
PL- 3
Completed Position No.16
Command Position No.32
GY- 1
8A
PC32
ZONE1
8B
GY- 3
Completed Position No.32
Brake Control Release
WT- 1
9A
BKRL
9B
WT- 3
Moving
Operation Mode Changeover
BK- 1
10A
RMOD
RMDS
10B
BK- 3
Zone
Home Return
BR- 2
11A
HOME
HEND
11B
BR- 4
Pause
RD- 2
12A
*STP
PEND
12B
RD- 4
Operating Mode Status (Manual Mode)
Start
OR- 2
13A
CSTR
SV
13B
OR- 4
Home Return Completion
Reset
YW- 2
14A
RES
*EMGS
14B
YW- 4
Position Completion
Servo ON
GN- 2
15A
SON
*ALM
*BALM
15B
GN- 4
Servo ON Status
BL- 2
16A
16B
BL- 4
Emergency Stop Status
PL- 2
17A
N
17B
PL- 4
Alarm
GY- 2
18A
N
18B
GY- 4
Absolute Battery
Voltage Drop Warning Output
WT- 2
19A
19B
WT- 4
BK- 2
20A
20B
BK- 4
SCON
PIO
Connector
PZONE
/ZONE2
Position Zone/Zone 2
“*” in codes above shows the signal of the active low. Processing occurs when an
input signal of the type is turned OFF. An output signal of the type is normally ON
in the power-on status and turned OFF at signal output.
�� Use the attached cable for the I/O connection.
Model : CB-PAC-PIO��� (��� indicates the cable length L. Example. 020 = 2m)
Half Pitch MIL Socket
HIF6-40D-1.27R (Hirose Electric)
Flat Cable (20-core) × 2
L
20A
20B
1A
1B
BK -4 (20B)
BK -2 (20A)
BR -3 (1B)
BR -1 (1A)
No connector
No connector