Bk+ pwr – IAI America SCON-CA User Manual
Page 77
Chapter 2 Wiring
67
� AC Power Supply Input Connector
Connector Name
AC Power Supply Input Connector
Cable Side
MSTB2-5/6-STF-5.08
Enclosed in standard package
Controller Side
MSTB2-5/6-GF-5.08
Note 1 The input power voltage cannot be changed after the delivery. Supply the power
voltage that meets the specification.
Pin No.
Signal Name
Contents
Applicable cable diameter
1
L1
Motor AC power input
2
L2
Motor AC power input
2mm
2
(AWG14)
3
L1C
Control AC power input
4
L2C
Control AC power input
0.75mm
2
(AWG18)
5
NC
Unconnected
6
PE
Protective ground line�
2mm
2
(AWG14)
Note 2 Field wiring terminals shall be marked with conductor material (Cu), insulation
temperature rating (More than 60�C) and tightening torque (0.5 ~ 0.6N•m).
� Brake Power Supply Connector
Connector Name
Brake Power Supply Connector
Cable Side
MC1.5/2-ST-3.5
Enclosed in standard package
Controller Side
MC1.5/2-G-3.5
Pin No.
Signal Name
Contents
Applicable cable diameter
BK+
24V DC power supply input
PWR-
24V DC ground
0.5mm
2
(AWG20)
BK+
PWR-
24V
0V