beautypg.com

5 loadcell (option) – IAI America SCON-CA User Manual

Page 42

background image

Chapter 1 Specifications Check

32

1.5.5 Loadcell (Option)

This is the pressing force detection unit that is used for the pressing operation using force sensor.

This is used by connecting to the actuator corresponding to the pressing operation using force

sensor.

[Specification]

Item

Specification

Loadcell System

Strain Gauge

Rated Capacity

20000N

Allowable Overload

200%R.C

*

An alarm occurs if:

Pressing force exceeds 150% of R.C*.

Tensile force exceeds 25% of R.C*.

Lordcell Accuracy

1%R.C

*

Zero

0.2%R.C

*

/10�C

Temperature

drift

Output

0.1%R.C

*

/10�C

Ambient temperature range

0 to 40�C

Dielectric strength voltage

50V DC

* R.C : Rated Capacity

[Installation Drawing]
Installation of loadcell on RCS2-RA13R

Check the Instruction Manual for details of how to attach and the dimensions.

Caution :

1) Do not give excess shock (caused by dropping it, etc.) to the loadcell. Failure to follow it

may cause the loadcell to be damaged.

2) The life of the loadcell is about two million pressing operation.

Loadcell