10.2 Way to Set Multiple Controllers with 1 Teaching Tool

It is usually necessary to connect the teaching tool to the controllers one by one when making a

setup to multiple controllers with one unit of teaching tool. In this section, explains how to

perform the settings without connecting and disconnecting the plug.

• Requisite devices :

(1) SIO Converter (RCB-TU-SIO-A or RCB-TU-SIO-B)� : 1 unit

(2) Controller Link Cable (CB-RCB-CTL002)�

: Required by the number of controllers

Accessories 1) 4-way junction (Manufactured by AMP 5-1473574-4)

: 1 unit

2) e-CON Connector (Manufactured by AMP 4-1473574-4) : 1 unit

3) Terminal Resistance (220��with a e-CON connector)

: 1 unit

Instead of the e-CON cable attached to the controller link cable, a terminal block may be used.

In this configuration, disconnect the e-CON connector from the controller link cable.

10.2.1 Connecting Example

Shown below is an example of connection.

Teaching Pendant

To be prepared by customer.

Cable included in PC software

PC Software

(Option)

RS232C-compatible

USB-compatible

SIO Converter (with Terminal Resistor)

Vertical

Horizontal

e-CON Connector (Manufactured by AMP 4-1473562-4 : Housing Color Green)
e-CON Connector (Manufactured by AMP 3-1473562-4 : Housing Color Orange)
Junction (Manufactured by AMP 5-1473574-4)

GN

GN

GN

Terminal Resistance

R = 220Ω

Controller Link Cable

Axis No. Setting : 0

Axis No. Setting : n-1

Axis No. Setting : 1

1st unit

nth unit

2nd unit