Chapter 10

Appendix

333

10.4.2 Specifications and Limitations in Pressing Operation of RCS2-RA13R

[1] Pressing Force and Current-Limiting Value

� Figure of mutual relation between pressing force and current limit value

Note : � The relation between pressing force and current limit value is shown with

reference values at the rating pressing speed (set at shipment).

Apply a pressing force larger than the minimum pressing force to the actuator. If

not, the pressing force can be unstable.

If it becomes necessary to change the pressing speed, contact us.

The positioning speed, a operation condition, should not be set to be less than

the pressing speed. Failure to follow this causes the pressing speed to be the

setting speed, which cannot bring proper pressing force.

Pressing Force [N]

Lead 1.25

Lead 2.5

Current-Limiting Value (%)