Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual
Page 647
Battery Commands
Wavecom Battery Charge Management +WBCM
©Restricted
Page:
99 / 158
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 4
August 23, 2007
°C
mV
°C
mV
°C
mV
0
1495
5
1399
10
1293
1
1477
6
1378
11
1271
2
1458
7
1357
12
1249
3
1438
8
1336
13
1226
4
1419
9
1315
14
1203
These values are obtained with the NTC equal to the Pull-up (Wavecom recommends
100K) and the NTC is polarized with the VCC_1V8 signal. Please refer to the battery
application note and the Customer Design Guidelines for more information
°C
mV
°C
mV
°C
mV
31
817
36
714
41
619
32
796
37
694
42
601
33
775
38
675
43
584
34
754
39
656
44
567
35
734
40
637
45
550
These values are obtained with the NTC equal to the Pull-up (Wavecom recommends
100K) and the NTC is polarized with the VCC_1V8 signal. Please refer to the battery
application note and the Customer Design Guidelines for more information