Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual
Page 238

Call Control Commands
Wavecom Hang-up +WATH
©Restricted
Page:
48 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 2
August 23, 2007
12.7.3
Parameters and Defined Values
release cause
range: 1-127
integerl value
Please refer to section "Failure Cause from GSM 04.08
recommendation" in the Appendixes chapter of this guide.
release location
Please refer to ETSI GSM 24.008 [8] for values.
0
user
1
private network serving the local user
2
transit
network
3
transit
network
4
public network serving the remote user
5
private network serving the remote user
7
international
network
10
network beyond inter-working point
12.7.4
Parameter Storage
None.
12.7.5
Examples
Command
Responses
AT+WATH=?
+WATH: (1-127),(0-5,7,10)
OK
AT+WATH=31
Note: Ask for disconnection with release
cause=normal and location=USER
OK
Note: All calls, if any, are released
AT+WATH=17,2
Note: Ask for disconnection with release
cause=user busy and location= public network
serving the local user
OK
Note: All calls, if any, are released