beautypg.com

Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 644

background image


Battery Commands

Wavecom Battery Charge Management +WBCM

©Restricted

Page:

96 / 158

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 4

August 23, 2007

: maximum duration in minutes of the pulse

charging

range: 60-90 (default value: 90)

: maximum duration in minutes of the constant

current charge

range: 60-90 (default value: 90)

:

battery status returned by AT+WBCM=2

command

2

battery currently in charge, the

parameter is also present

3

battery currently out of charge, the

parameter is also present

:

battery status returned as +WBCI unsolicited

response

0

minimum battery level reached. The battery is

considered as discharged

The product is turned off (as with the +CPOF

command) if a charger is not plugged. Else the

charge automatically begins

not dependent on the parameter

1

maximum battery level reached (the battery is

considered as charged) or charging

discontinuation

The battery charging is stopped

not dependent on the parameter

2

battery currently in charge, the

parameter is also present

3

battery currently out of charge, the

parameter is also present

4

charger has been plugged, appears only when

is set to 2

5

charger has been unplugged, appears only when

is set to 2

6

unusual voltage or temperature (Li-ion charging

algorithm only), appears only when

is set to 2

:

current battery voltage in mV during or out of

charging

range: 2800-4300