13.5.3
Parameters and Defined Values
behaviour in case of bad radio link
0
data communication is hung up in case of bad radio link
1
data communication is held, even if the radio link is bad;
there is a possibility of losing data (default value)
power mode
0
normal
mode
1
economic battery mode, not supported by all networks
(default value)
13.5.4
Parameter Storage
Parameters are stored in EEPROM using the AT&W command. The default value can
be restored using AT&F.
13.5.5
Examples
Command
Responses
AT+DOPT=?
(0,1),(0,1)
OK
AT+DOPT=1
OK
Note: Second parameter is omitted
AT+DOPT=1,1
OK
Note: Set new parameters
AT+DOPT?
1,1
OK
AT+DOPT=,0
Note: First parameter is omitted
OK