SIM Commands
Restricted SIM Access +CRSM
©Restricted
Page:
130 / 202
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 3
August 23, 2007
18.4.3 Parameters and Defined Values
command passed on by the MT to the SIM (all other values are
reserved); refer to 3GPP 11.11 [9] (or 3GPP 51.011 [13]).
integer type (see note 1 below)
176 READ
BINARY
178 READ
RECORD
192 GET
RESPONSE
242 STATUS
identifier of an elementary data file on SIM
mandatory for every command except STATUS
integer type (see note 2 below)
These parameters are mandatory for every command, except
GET RESPONSE and STATUS. The values are described in 3GPP
11.11 [9] (or 3GPP 51.011 [13]).
integer type
:
information which is to be written to the SIM (hexadecimal
character format; refer to +CSCS)
hexadecimal type
information from the SIM about the execution of the actual
command
These parameters are delivered to the TE in both cases, on
successful or failed execution of the command.
integer type
response to successful completion of the command previously
issued (hexadecimal character format; refer to +CSCS)
STATUS and GET RESPONSE return data, which gives
information about the current elementary data field. This
information includes the file type and size (refer to 3GPP [9]
11.11 (or 3GPP 51.011[13]). After the READ BINARY or READ
RECORD command, the requested data will be returned.
hexadecimal type