GPRS Commands
GPRS parameters customization: +WGPRS
©Restricted
Page:
89 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 2
August 23, 2007
14.2.3
Parameters and Defined Values
Wavecom GPRS parameter
0
ATTACH-STATUS (the ME does not automatically perform a
GPRS attachment after initialization)
only
1
PDP-INIT-STATUS (declares some PDP contexts liable to be
activated automatically after initialization by
only
2
sets ACTIVABLE automatically after init a define PDP context
only
3
PPP silent mode (PPP waits for PPP Client to start the dialog)
only
4
definition of the GPRS multislot class. This parameter
represents the GPRS or EGPRS class chosen by the user to
perform power saving (by reducing TX /uplink time slots).
only
5
Slow CONNECT for PALM
®
OS (due to the delay of the
processing of PALM
®
OS, the CONNECT is sent one second
after the dialing command request)
only
6
PPP
Filtering
only
7
Automatic GPRS roaming inter-operator (ME automatically
reattaches itself to the network and reactivates its PDP
context by changing of operator when reaching border areas)
only
8
Definition of the EGPRS multislot class (available for EGPRS
compatible Wavecom Wireless CPU
®
s)
only
9
GPRS/EGPRS network capability indication (available for
EGPRS compatible Wavecom Wireless CPU
®
s)
requested operation for
0
disabled
1
enabled
2
only for
PDP context identifier
range: 1-4
integer type