Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual
Page 164

Serial Port Commands
Multi-flow Management +WMFM
©Restricted
Page:
158 / 184
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 1
August 23, 2007
:
data type
0 GSM
data
1 GPRS
data
physical port state
0 deactivated
1 activated
8.12.4
Parameter Storage
The
8.12.5
Examples
Command
Responses
AT+WMFM=?
+WMFM: 0,(0-2),(1-3,80)
+WMFM: 1,(0-2),(80,1),(0-1)
OK
Note: To manage incoming data, only UART 1 is
available
AT+WMFM=0,2
+WMFM: 0,2,1,1
+WMFM: 0,2,2,0
+WMFM: 0,2,3,0
OK
Note: Read state of all ports
Note: UART1 is opened
AT+WMFM=0,1,2
Note: Open UART2
OK
AT+WMFM=0,2,2
Note: Read UART2 state
+WMFM: 0,2,2,1
OK
AT+WMFM=1,2
+WMFM: 1,2,4,0
+WMFM: 1,2,4,1
OK
Note: Read attachments of ports to which data are
redirected
Note: GSM and GPRS data are dynamic