beautypg.com

Rainbow Electronics FARGO MAESTRO 100 (with TCP_IP) User Manual

Page 61

background image


Global Configuration Commands

Hardware Configuration +WHCNF

©Restricted

Page:

55 / 184

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 1

August 23, 2007

Command

Responses

AT+CFUN=1

Note: Reset the Wireless CPU

®

OK

AT+WHCNF=3,3

Note: Get the external SIM switch status

+WHCNF: 3,1,0

OK

Note: The third parameter <0> indicates that the external

SIM feature is taken into account

AT+WHCNF=0,2

Note: Interrogate the keypad status

+WHCNF: 0,0

OK

AT+CMER?

+CMER: 3,1,0,0,0

OK

Note: After the keypad is deactivated, no unsolicited result is

sent when a key is pressed or released.

AT&F

Note: Restore factory settings

OK

AT+WHCNF=0,2

+WHCNF: 0,1

OK

AT+WHCNF=1,2

+WHCNF: 1,1,1

OK

Note: The third parameter <1> indicates a Wireless CPU

®

reset is needed.

AT+WHCNF=2,2

+WHCNF: 2,0

OK

AT+WHCNF=0,1

Note: Activate the keypad

OK

6.2.6

Notes

To activate the External SIM switch with this command, you must select a single

voltage (i.e. 3v only or 1v8 only) with the Wavecom feature command (AT+WFM).

This voltage will be used by the electrical SIM interface of the Wireless CPU

®

. The

selection with AT+WFM must be the current settings (i.e. the reset flag must be

equal to 0)