GSM Network Commands
Wavecom Location +WLOC
©Restricted
Page:
26 / 156
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 2
August 23, 2007
11.6.3
Parameters and Defined Values
requested operation
0
stop automatic shots
1
one shot requested
2
automatic shots requested (every x seconds)
3
configuration of the
time period for automatic shots
range: 5-255 (multiple of 5, default value 5)
If omitted, the value will be set to 5.
requested measurements
bitfield: 1-255 (default value:255)
If omitted, the value will be set to 255.
1
date and time will be returned in the response
2
TA will be returned in the response
4
BCCH will be returned in the response
8
network measurements will be returned in the response
16
CI will be returned in the response
32
LAC will be returned in the response
64
MNC-MCC will be returned in the response
MCC and MNC codes
3 bytes in hexadecimal format (network coding)
>: Location Area Code string type; two byte location area code in hexadecimal format (e.g. "00C3" equals 195 in decimal) Cell Id string type; two bytes in hexadecimal format If the Cell Id is not available, this parameter is omitted. network measurements 16 bytes in hexadecimal format