18.3.3 Parameters and Defined Values
Length of the characters that are sent to TE in
response). For command sent to TE, this value must be in the
range [ 10 – 522 ], else a "+CME ERROR: 3" is returned.
integer type
Command passed on by the MT to the SIM in the format as
described in 3GPP 11.11 [9] (or 3GPP 51.011 [13]) (hexadecimal
character format; see the +CSCS command).
The supported commands are :
READ BINARY
READ RECORD
FETCH
STATUS
SELECT
SEEK
TERMINAL RESPONSE
ENVELOPE
TERMINAL RESPONSE
hexadecimal type
Second Byte Value not supported:
Due to the absence of locking, a "CME_ERROR: 3" is returned for
the following instructions ( See CRSM commands):
• D6 : UPDATE BINARY
• DC : UPDATE RECORD
• 32 : INCREASE
• 44 : REHABILITATE
• 04 : INVALIDATE
• 88 : RUN GSM ALGORITHM
• 20 : VERIFY CHV
• 24 : CHANGE CHV
• 26 : DISABLE CHV
• 28 : ENABLE CHV
• 2C : UNBLOCK CHV
• FA : SLEEP
• C0 : GET RESPONSE
Second Byte Value warning:
Due to the absence of locking, the right response may not be