PLMN Commands

Preferred Operator List +CPOL

©Restricted

Page:

146 / 156

This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.

WM_DEV_OAT_UGD_049 - 001

VOLUME 2

August 23, 2007

15.3.6 Notes
The different possibilities are:

• AT+CPOL=, to delete an entry.
• AT+CPOL=,, to set the format used by the read command

(AT+CPOL?).

• AT+CPOL=,,, to put in the next free location.
• AT+CPOL=,,, to write in the at the

.

• AT+CPOL=,,,,,

>, to write in the at the giving the access

technology (in the case of EF_PLMNwact, EF_HPLMNwact or EF_OPLMNwact

is present).

Note:

If access technology parameters are not given, the GSM access technology will be

chosen.

The supported formats are those of the +COPS command. The length of this list is

limited to 85 entries for EF_PLMNsel, and 51 for EF_PLMNwAct, EF_OPLMNwAct,

EF_HPLMNwAct.