Battery Commands
Wavecom Battery Charge Management +WBCM
©Restricted
Page:
94 / 158
This document is the sole and exclusive property of Wavecom. Not to be distributed or divulged without
prior written agreement.
WM_DEV_OAT_UGD_049 - 001
VOLUME 4
August 23, 2007
23.2.3
Parameters and Defined Values
requested operation
0
stop the battery charging (default).
1
start the battery charging
2
get the current battery voltage
3
set the battery charge parameters
4
choose the type of charging
battery charge unsolicited indication mode
0
disable the battery charge unsolicited indications (default
value)
1
enable the battery charge unsolicited indications.
2
enable the extended battery charge unsolicited indications
charging algorithm
0 NI-CD,
NI-MH
1 Li-ion
2
get the charging algorithm
maximum level for the battery voltage in mV
When reached, the battery is considered as charged
range: 3800-4300 (default value: 4200)
minimum level for the battery voltage in mV
When reached, the battery is considered as
discharged and the product is turned off (with the
+CPOF command behavior)
range: 3200-3800 (default value: 3200)
time in ms between pulses for the pulsed charge
range: 100-10000 (default value: 100)
< WBCITimer >:
time in ms between +WBCI unsolicited responses in
or out of charge (for
range: 1000-10000 (default value: 2000)