Page 98

background image

6-36

Modular Block System: Hydraulic Presses

Standard Function Blocks

Procedure for achieving the enable (output parameter

ENBL) when PSS is

in RUN mode (subsequent statuses only after enable is issued)

Op. mode

Reset

ARSt

0

1

0

0

1

1

lock

Parameter

AuSt

0

0

0

1

*1

0

1

*1

NoFT

0

0

1

1

1

1

Func- Status of gate

open shut open shut open shut open shut open shut open shut

tion

Close gate

x

-

x

-

x

-

x

-

x

-

x

-

test Open and close

-

-

-

-

-

-

-

-

-

-

-

-

gate
RSET

-

-

-

Table 2: Function: “Reset lock”

Required reaction from operator in the case of a fault

Parameter

ARSt

0

1

0

0

1

1

AuSt

0

0

0

1

*1

0

1

*1

NoFT

0

0

1

1

1

1

Funk- Status of gate

open shut open shut open shut open shut open shut open shut

tion

Close gate

x

-

x

-

x

-

x

-

x

-

x

-

test Open and close

x*

4

x

x*

4

x

x

4

x

x*

4

x

x*

4

x

x*

4

x

gate
RSET

-

-

-

Table 3: Reaction in the case of a fault

x Function activated or

operator reaction required

-

Function not activated or
no operator reaction required or
reset not required

Reset required via the reset input

*1

The function “No start-up disabler on PSS cold/warm start” is only
possible when no function test is set (

NoFT = 1).

*2

First close the gate, then open it and close it again.

*3

The enable can be set by opening/closing the gate or by a pulse at the

reset input.

*4

When synchronisation time

S1-S2 is exceeded (error bit 09)

SB064