Modular Block System: Hydraulic Presses
Safety gate monitoring with guard locking, automatic start and manual
restart, category 4
Block used: SB075/GRD_LCK
Cyclical function test on the gate:
The following application does not require a cyclical function test on the
gate.
However, if you need this requirement, the “Machine running” signal
should be assigned to the input parameter
MRun.
Set operating mode:
The following operating mode is set in this application:
ARSt = 0: Reset lock activated (manual restart)
The operator must acknowledge each opening of the safety gate
(input parameter
RSET).
NoFT = 1
No function test on the gate when the PSS is cold/warm started,
when the I/O-Group is started or each time the gate is unlocked
AuSt = 1
No start-up disabler (automatic start)
WARNING!
When a safety-related device provides a start or restart signal, the start or
restart shall take place automatically only if a hazardous situation cannot
exist (EN 954, 03/97).
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license