Sb052: operating mode selector switch, 2 from 6, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual

Page 72: Standard function blocks, Sb052

background image

6-10

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB052: Operating mode selector switch, 2 from 6

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB 001 ... KB 200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).

S1 ... S6: Switch levels from coded operating mode selector switch

On each position of the selector switch, a 1-signal must be
present at two switch contacts only.

If a maximum of 6 switch settings (operating modes) are used,
switch contacts S5 and S6 may be omitted (see table overleaf:
“Input coding of selector switch”).
If a maximum of 10 switch settings are used, switch contact S6
may be omitted (see table overleaf: “Input coding of selector
switch”).

Unused inputs should be assigned RLO-0 (M 110.00).

SB052

BA_2AUS6

B - SSNR
X - S1
X - S2
X - S3
X - S4
X - S5
X - S6
X - RSet
X - LOCK
W- TIME

FG

- X

BA

- W

RSET - X

SB052