Output parameters – Pilz PSS SB HYD, Basic license User Manual
Page 221

Modular Block System: Hydraulic Presses
6-159
AuSt = 1:
Automatic start when PSS starts up
To set automatic start-up on the SB, the input
parameter should be assigned RLO-1 (M 110.01).
•
ARst:
Automatic restart/reset lock after the enable switch is released
or unlatched from stage 3
ARst = 0:
Reset lock
After the enable switch is released / unlatched, a
reset via the input parameter
RSET is required.
To set the reset lock on the SB, the input
parameter should be assigned RLO-0 (M 110.00).
ARst = 1:
Automatic restart after the enable switch is
released / unlatched from stage 3
To set automatic restart for the SB, the input
parameter should be assigned RLO-1 (M 110.01).
•
RSET:
Error reset
RSET = 0/1-pulse edge: Reset error
Output parameters
•
ENBL:
Enable flag bit
ENBL = 0: Not enabled
i.e. no approval
ENBL = 1: Enabled
i.e. approval
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license