Output parameters – Pilz PSS SB HYD, Basic license User Manual

Page 221

background image

Modular Block System: Hydraulic Presses

6-159

AuSt = 1:

Automatic start when PSS starts up
To set automatic start-up on the SB, the input
parameter should be assigned RLO-1 (M 110.01).

ARst:

Automatic restart/reset lock after the enable switch is released
or unlatched from stage 3
ARst = 0:

Reset lock
After the enable switch is released / unlatched, a
reset via the input parameter

RSET is required.

To set the reset lock on the SB, the input
parameter should be assigned RLO-0 (M 110.00).

ARst = 1:

Automatic restart after the enable switch is
released / unlatched from stage 3
To set automatic restart for the SB, the input
parameter should be assigned RLO-1 (M 110.01).

RSET:

Error reset
RSET = 0/1-pulse edge: Reset error

Output parameters

ENBL:

Enable flag bit
ENBL = 0: Not enabled

i.e. no approval

ENBL = 1: Enabled

i.e. approval