Output parameters, Standard function blocks sb069 – Pilz PSS SB HYD, Basic license User Manual
Page 136

6-74
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB069
Wiring the input parameters
Wiring for category 2 (ESPE/AOPD Type 2)
It is sufficient to use one output signal from the ESPE/AOPD. In this case,
parameters for input parameters
NO_1 and NO_2 should be set for the
same input.
WARNING!
If only one signal is used, certain faults will not be detected. For this
reason you should carry out a function test of the ESPE/AOPD at regular
intervals. This requirement can be met by requesting an automatic
function test at appropriate intervals via the input parameter
Test.
Wiring for category 4 (ESPE/AOPD type 4)
To achieve category 4 you will need to use two output signals from the
ESPE/AOPD. Type 4 ESPE/AOPD devices with semiconductor outputs
can be connected to DI 2 inputs (e.g. input module PSS(1) DI 2) in order to
meet the requirements of category 4.
Test pulses
If the relay outputs of the ESPE/AOPD do not have their own test pulse
signals, these will need to be set via the PSS.
Output parameters
•
ENBL :
Enable bit
ENBL = 0: Protected field broken
ENBL = 1: Protected field clear
The enable is issued if the protected field is clear
(
NO_1 = 1, NO_2 = 1) and no faults are present.
•
TEST:
Test output
TEST = 0: Simulated break in protected field
Function test of ESPE/AOPD by switching off the
ESPE/AOPD emitter
TEST = 1: ESPE/AOPD emitter in operation
•
PWR:
Output for switching the operating voltage to the ESPE/AOPD
(POWER)
PWR = 0:
ESPE/AOPD switched off
PWR = 1:
ESPE/AOPD switched on
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license