beautypg.com

Pilz PSS SB HYD, Basic license User Manual

Page 81

background image

Modular Block System: Hydraulic Presses

6-19

INFORMATION
The two-hand device/console is correctly disconnected and deselected
when:

Input parameter

T1.2 and T1.4 = 0
T2.2 and T2.4 = 0

Output parameter

FG, GST, AUF = 0
OFF = 1

In all cases, an error message will be issued when a two-hand device/
console is disconnected. You will need to take one of the following actions:
• The two-hand device/console is disconnected, but still selected via the

key switch:
Deselect the console via the key switch and then reset.
The two-hand device/console is now correctly deselected and
disconnected (please refer to “Error messages” under “Bit 04”).

• The two-hand device/console is deselected via the key switch, but is still

connected:
Disconnect the console and then reset.
The two-hand device/console is now correctly deselected and
disconnected (please refer to “Error messages” under “Bit 05”).

A dummy connector is not required to act as a buffer when unplugging
a two-hand device/console.

DANGER!

If a two-hand circuit is deselected using the input parameter

Off, a diffe-

rent safety device must be employed in its place.
Remember that the two-hand circuit has a safety function in addition
to its operator function.