Pilz PSS SB HYD, Basic license User Manual
Page 81

Modular Block System: Hydraulic Presses
6-19
INFORMATION
The two-hand device/console is correctly disconnected and deselected
when:
Input parameter
T1.2 and T1.4 = 0
T2.2 and T2.4 = 0
Output parameter
FG, GST, AUF = 0
OFF = 1
In all cases, an error message will be issued when a two-hand device/
console is disconnected. You will need to take one of the following actions:
• The two-hand device/console is disconnected, but still selected via the
key switch:
Deselect the console via the key switch and then reset.
The two-hand device/console is now correctly deselected and
disconnected (please refer to “Error messages” under “Bit 04”).
• The two-hand device/console is deselected via the key switch, but is still
connected:
Disconnect the console and then reset.
The two-hand device/console is now correctly deselected and
disconnected (please refer to “Error messages” under “Bit 05”).
A dummy connector is not required to act as a buffer when unplugging
a two-hand device/console.
DANGER!
If a two-hand circuit is deselected using the input parameter
Off, a diffe-
rent safety device must be employed in its place.
Remember that the two-hand circuit has a safety function in addition
to its operator function.
- PSS SB HYD, General license PSS SB HYD, Copy license PSS SB HYD, Update license PSS SB TRA, Basic License PSS SB TRA, General license PSS SB TRA, Copy license PSS SB TRA, Update license PSS SB NOT, Basic license PSS SB NOT, general license PSS SB NOT, Copy license PSS SB NOT, Update license PSS SB FT, Basic license PSS SB FT, General license PSS SB FT, Copy license